Click Here to Visit Our Industrial IIoT Portfolio →
Facility & Warehouse Safety — Headcount Management

Headcount Management System

Maintain real-time count of people present in your facility with precision. Bi-directional IN/OUT tracking with LED display. 99.9% accuracy, POE powered, designed for industrial environments.

Real-Time Counting 140° Horizontal FOV POE Powered
Product Image — Headcount Management System Drive: Headcount management / Photos

The Problem

Manual headcount tracking is error-prone, time-consuming, and provides no real-time visibility. Inaccurate occupancy data leads to safety compliance issues, operational inefficiency, and inability to respond to emergencies.

  • Manual counting errors — Human-based headcount is slow, unreliable, and impossible to maintain continuously across multiple facilities or zones.
  • No real-time visibility — Lack of accurate occupancy data prevents informed decision-making about capacity, emergencies, and resource allocation.
  • Safety & compliance gaps — Unable to verify personnel presence during emergencies or maintain occupancy compliance with regulatory requirements.
  • Peak period challenges — Cannot track facility dynamics during high-volume periods, leading to overcrowding and potential safety violations.
Deployment Photo Drive: Headcount management / Photos

How It Works

01

Depth Sensor Detection

Advanced depth mapping continuously monitors entry/exit areas with 140° horizontal and 120° vertical field of view, capturing every movement.

02

Bi-Directional Tracking

Intelligent algorithms distinguish between IN and OUT movements, maintaining accurate directional counting across monitored zone.

03

Real-Time Processing

Data processed at 25fps with onboard memory ensures continuous operation, even during connectivity interruptions.

04

Display & Integration

LED display shows live headcount. Ethernet connectivity enables integration with facility management and safety systems.

Key Features

99.9% Accuracy

Industry-leading accuracy in real-time people counting ensures reliable occupancy data for safety and compliance.

LED Display Output

Built-in LED display shows current headcount at a glance, visible to staff and management in real-time.

POE Powered

Power over Ethernet simplifies installation—single cable for power and data. Fallback to 12V DC external supply available.

Bi-Directional Counting

Distinguishes IN and OUT movements independently, providing directional occupancy insights for each monitored zone.

Robust Operation

IP54 rating handles industrial environments. Operating range: 0°C to 60°C, humidity 0-99%. Built-in memory for data continuity.

Flexible Installation

Configurable height range (1.9m–3.2m) and coverage range (1.1m–7.0m). Filter height adjustment (0.5m–1.2m) for precise zone detection.

Technical Specifications

Data from product datasheet. Headcount system specifications with depth sensing technology.

Parameter Value
Communication Type Ethernet
Installation Environment Indoor
Count Facility Multiple Head Counting
IP Grade IP54 Compatible
Direction IN/OUT Bi-directional
Inbuilt Memory Yes
Operating Temperature 0°C to 60°C
Humidity Range 0% to 99%

System Integrations

Facility Management Systems Safety Platforms Building Automation Emergency Response Systems Occupancy Analytics

Can be integrated with facility management and safety systems. Customized configurations and extended support available on request.

Applications

Warehouse Safety

Track personnel in restricted zones and high-risk areas to ensure compliance and quick response during emergencies.

Facility Capacity

Monitor real-time occupancy to prevent overcrowding and maintain safe facility utilization during peak operations.

Emergency Evacuation

Provide accurate headcount during evacuations to verify all personnel have safely exited the facility.

Access Control Validation

Validate entry/exit counts against access logs to detect unauthorized movement and maintain security.

Operational Efficiency

Optimize resource allocation and staffing based on real-time occupancy patterns and zone utilization data.

Installation & Integration

Mounting & Installation

Install at height 1.9m–3.2m above floor level, typically at doorways or entry/exit points. Ensure clear line of sight with 140° horizontal coverage for optimal detection.

Configuration & Calibration

Configure detection zones, filter heights, and direction sensitivity based on facility layout. Define IN/OUT thresholds and configure LED display behavior.

Network Integration

Connect via Ethernet to facility network. Configure IP settings and integrate with facility management systems for centralized monitoring and reporting.

Testing & Validation

Perform system calibration and accuracy testing. Validate counting performance and configure alerts for occupancy thresholds and emergency conditions.